Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Water Treatment Case
Guangzhou Chunke Environmental Technology Co., Ltd.
Home ProductsEDI Water Treatment Plant

1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant

China Guangzhou Chunke Environmental Technology Co., Ltd. certification
China Guangzhou Chunke Environmental Technology Co., Ltd. certification
Hi Jessie, The 5T/H RO water plant was running well ! Perfect quality and excellent service ! Thank you so much Hunter ! I will place more order in near future surely !

—— Reid from Australia

We have been doing business with Chunke company for many years with high performance-cost and friendly service , such a honest factory, product are good !

—— Edward from South Africa

Hello cara,I received the water Filter last week.It look SUPER !!! Thanks !!! Thank you my friend !!!

—— Joice from Poland

It's many times buy from here. And always giving professional suggestions, help me a lot in business! Thanks!

—— Fraser from Russia

Good price , good quality and fast delivering .

—— Robert From UK

The brackish water machine is very suitable for my project and I have purchased it for the second time.

—— Hassan from Saudi Arabia

I'm Online Chat Now

1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant

1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant
1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant
video play

Large Image :  1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant

Product Details:
Place of Origin: CHINA
Brand Name: CHUNKE
Certification: CE,ISO
Model Number: CK-EDI
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Negotiate
Packaging Details: Wooden or carton
Delivery Time: 15-30 working days
Payment Terms: L/C, T/T, Western Union,paypal
Supply Ability: 20 units per month
Detailed Product Description
Material: Stainless Steel Automatic Grade: Full Automatic
After-sales Service Provided: Online Support,Field Installation, Commissioning And Training Application: Purification
Control: Automatic/ Manual Certification: ISO9001,RoHS,SASO,CE
Warranty: 1 Year Flow Rate: 1m³ Per Hour

1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant
 
Advantage of the EDI system
1.System can produce water continuously and high degree automation.
2.No need chemical to regenerate, easy operation and maintenance.
3.Core components of ro system are imported USA membranes.
4.Automatic switch on when low water level, and switch off when high water level
5.System flushes RO membranes automatically, reducing membranes polluted speed.
6.Water shortage protection for multi-stage pump
7.Product water conductivity meter can monitor water quality online continuously.
8.Low operation cost and long life span
 
Detail image of the 2 stage RO+EDI system
1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant 0
1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant 1
1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant 2
1000lph 2 Stage RO Water Purification System With Edi Module Treatment Plant 3
 
Customized Capacity
 

Model

Productivity
(T/H)

Motor power
(KW)

Recovery rate
(%)

Outlet water conductivity
(μS/CM)

Raw water conductivity
(μS/CM)

CK-RO-500L0.51.550≤10≤300
CK-RO-1000L12.250≤10≤300
CK-RO-2000L2350-60≤10≤300
CK-RO-3000L34.555-65≤10≤300
CK-RO-4000L46.555-65≤10≤300
CK-RO-5000L5860-70≤10≤300
CK-RO-10000L101560-70≤10≤300
CK-RO-20000L202265-75≤10≤300
CK-RO-30000L302670-75≤10≤300
CK-RO-50000L505570-75≤10≤300

 
One stage reverse osmosis system:
After the coarsely filtered water passes through the reverse osmosis membrane, it is a first-order reverse osmosis. The reverse osmosis membrane is a semi-permeable membrane, which can prevent large ions such as Ga2 +, Mg2 +, Fe-2, SO4-2, Cl-1, Na + from passing through. To ensure the effect of reverse osmosis and protect the reverse osmosis membrane, the scale inhibitor must be continuously added to the reverse osmosis container. At the same time, the water temperature must be above 25 ° C (using a steam heat exchanger in winter) and a certain water pressure. (Pump) Under a certain pressure, ion-containing water is squeezed through the reverse osmosis membrane to form two kinds of water. The water that passes through the reverse osmosis membrane, that is, the finished water, enters the next link, and the water that does not pass through the reverse osmosis membrane is discharged After the first-stage reverse osmosis treatment, the water enters the next stage-the second stage reverse osmosis.
Two stage reverse osmosis system:
The principle of the second-stage reverse osmosis is the same as that of the first-stage reverse osmosis. Its role is to further remove the salt in the water. After reverse osmosis, the water quality conductivity can approach 1MΩ.CM. After the first and second stage reverse osmosis pretreatment, the last remaining water becomes the feedwater of EDI, and the water (concentrated water) that has not passed through the reverse osmosis membrane is discharged in time. The ratio is generally 1: 3, which means that each ton produced Of qualified water, about 3 tons of concentrated water (reclaimed water) should be drained.
EDI (Electro deionization) processing:
The secondary reverse osmosis water is stored in the intermediate water tank, and more than 99% of its ions have been removed. However, to further improve the water quality and produce ultrapure water, the trace elements and CO2 dissolved in the water must also be passed through electricity. Dialysis, or EDI treatment, has the following principles. EDI, or continuous electrosalt removal, uses mixed ion exchange resins to adsorb anions and cations in water. At the same time, these adsorbed ions pass through anion and cation exchange under the action of DC voltage. The film is removed. In this process, the ion exchange resin is continuously regenerated electrically, so it is not necessary to use acid and alkali to regenerate it. This technology can replace traditional ion exchange devices and produce ultra-pure water with a resistivity of up to 18MΩ.CM. This process technology is known as a revolution in the water treatment industry. Compared with traditional ion exchange, EDI has the following advantages: EDI does not require chemical regeneration; EDI does not require downtime during regeneration; provides stable water quality; low energy consumption; easy operation, low labor intensity, and low operating costs.
 