Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Water Treatment Case
Guangzhou Chunke Environmental Technology Co., Ltd.
Home ProductsBrackish Water Treatment Plant

380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification

China Guangzhou Chunke Environmental Technology Co., Ltd. certification
China Guangzhou Chunke Environmental Technology Co., Ltd. certification
Hi Jessie, The 5T/H RO water plant was running well ! Perfect quality and excellent service ! Thank you so much Hunter ! I will place more order in near future surely !

—— Reid from Australia

We have been doing business with Chunke company for many years with high performance-cost and friendly service , such a honest factory, product are good !

—— Edward from South Africa

Hello cara,I received the water Filter last week.It look SUPER !!! Thanks !!! Thank you my friend !!!

—— Joice from Poland

It's many times buy from here. And always giving professional suggestions, help me a lot in business! Thanks!

—— Fraser from Russia

Good price , good quality and fast delivering .

—— Robert From UK

The brackish water machine is very suitable for my project and I have purchased it for the second time.

—— Hassan from Saudi Arabia

I'm Online Chat Now

380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification

380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification
380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification 380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification 380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification 380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification

Large Image :  380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification

Product Details:
Place of Origin: Guangzhou,China
Brand Name: Chunke
Certification: CE,ISO
Model Number: CK-BW
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Discussible
Packaging Details: Standard package
Delivery Time: 7-15 working days
Supply Ability: 1000 unit per month
Detailed Product Description
Item: 380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification Recovery Efficiency: 60%~65%
Desalinate Rate:: ≥98 Membrane: DOW/Vontrone/GE
Certification: ISO9001 CE Control Method: Full Control Or Semiconductor
Power Supply: 220 / 380V Weight: Depends
Color: Green
High Light:

brackish water reverse osmosis

,

brackish water ro system

380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification

 

First, the pretreatment system is washing and backwashing is the first step of equipment purification.

 

1. Large-capacity equipment is equipped with a multi-media filter, an activated carbon filter, and a softened resin filter (optional). Through the

 

forward and reverse flushing of the pretreatment system, the raw water quality can be more easily reached to the influent standard of pure

 

water, and the normal life of the reverse osmosis membrane is guaranteed. In daily use and maintenance, regular positive and negative rinsing

 

operations can remove impurities and impurities remaining in each filter. In addition, activated carbon filtration is mainly used to remove free

 

chlorine, color, microorganisms, organic matter and some heavy metals and other harmful substances in water. Prevent them from affecting the

 

reverse osmosis membrane system. Because the activated carbon filter will retain most of the organic matter and impurities, it is a breeding

 

ground for bacteria. Therefore, it is necessary to periodically replace the activated carbon filter material in it. The softening resin is a special

 

resin for softening hard water, and the hardness of water is lowered by ion exchange technology. When the soft water resin replaces a certain

 

amount of hardness ions such as calcium and magnesium in water, it will not be able to soften the water. At this time, it is necessary to soften

 

the filter for resin regeneration. For normal regeneration, it is necessary to ensure sufficient salt and water in the salt tank. . In addition, a scale

 

inhibitor dosing device can be selected, and a scale inhibitor is added to the reverse osmosis water to prevent the insoluble salts such as

 

calcium carbonate, magnesium carbonate and calcium sulfate in the reverse osmosis concentrated water from being concentrated, and the

 

scale precipitates to block the reverse osmosis membrane, thereby Guarantee the life of the membrane components.

 

2. Equipment with small processing capacity is equipped with a filter element as a pretreatment filter. Generally, there are PP,

 

etc., and it is only necessary to replace it according to the quality of the raw water.

 

3. The reverse osmosis membrane will be automatically cleaned during the normal operation of the equipment, and daily use

 

only needs to be replaced regularly.

 

Second, it is necessary to pay special attention to: the equipment pressure (inlet water pressure, working pressure) must meet the standard,

 

otherwise it will easily cause the equipment to have insufficient water output, and the equipment air consumption will easily cause equipment damage.

 

Third, for equipment equipped with precision filters, it is necessary to replace the filter element regularly to ensure the quality of water in the equipment. When the pure water equipment stops running, it must be cut off and power off, and the security facilities should be completed.

 

4. Regularly monitor the quality of the produced water.

 

If the water conductivity (or TDS value) of the equipment is higher than our standard value, the production of water should be stopped and the

 

reverse osmosis membrane should be cleaned or replaced.

 

The daily maintenance precautions for pure water equipment have the following points:

 

1. Be careful to replace the filter element in time. Now people's health awareness is getting stronger and stronger, and the requirements for

 

water quality are getting higher and higher. The filter elements of pure water equipment must be replaced in time to ensure water quality and

 

ensure the taste of water.

 

2. A fault is resolved in time. In the process of running pure water equipment, if there is a fault, it should be repaired and maintained in time to

 

avoid minor problems becoming big troubles.

 

3. The reverse osmosis membrane needs to be cleaned in time. Under normal circumstances, the equipment will automatically clean the

 

reverse osmosis membrane, and manual cleaning is required in some special cases. During the cleaning, the reverse osmosis membrane

 

element does not produce water, so that the cleaning water flows along the surface of the diaphragm at a high speed, and the pollutants

 

deposited on the surface of the membrane are completely washed out of the system, completely eliminating the possibility of breeding bacteria

 

in the pipeline, and improving the effluent of the reverse osmosis water. quality.

 

4. Do not arbitrarily adjust the valve ratio, working pressure and other valves. Each type of equipment has a corresponding parameter range. In

 

addition, depending on the environment, it will be set after installation. Unauthorized adjustment can result in reduced filter life or equipment

 

failure.

 

 

380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification 0380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification 1380V Reverse Osmosis System Brackish Water Treatment Plant With CE Certification 2

 

 

 

Contact Details
Guangzhou Chunke Environmental Technology Co., Ltd.

Contact Person: Jessie

Tel: +8617502033136

Send your inquiry directly to us (0 / 3000)