|
Place of Origin | Zhengzhou,China |
Brand Name | HYJB |
Model Number | 0.25T Single Stage |
0.25T Single Stage Nanofiltration Membrane For RO Mineral Water Treatment Plant And Water Purification
Production Description:
Reverse osmosis pure water equipment adopts automatic control mode to reduce the influence of human error operation on the equipment belt. In the pretreatment system, the design of reduction system was adopted to solve the irreparable effect of excessive residual chlorine on the reverse osmosis membrane. The reverse osmosis membrane selection adopts the original imported reverse osmosis membrane from the United States, which has a service life of up to 3 years and an effluent conductivity of less than 5us. Pump selection of domestic south pump and imported Grundfos pump, low noise, long service life. We use Dow Company's professional design software, the recovery rate can reach more than 65%. High degree of automation, simple operation, stable water quality, low operating costs are well received.
Parameter Table:
Model
|
Water Making Ability
|
Inlet Caliber
|
Effluent Caliber
|
Blowdown alCer
|
Size(mm)
|
Power
|
YSRO-0.5T
|
0.5m3/h
|
DN20
|
DN20
|
DN15
|
1500×600×1500
|
1.3kw
|
YSRO-1T
|
1m3/h
|
DN25
|
DN25
|
DN20
|
1700×600×1500
|
2.1kw
|
YSRO-2T
|
2m3/h
|
DN32
|
DN25
|
DN20
|
2500×1000×1950
|
4.4kw
|
YSRO-3T
|
3m3/h
|
DN40
|
DN32
|
DN25
|
2500×1200×2150
|
4.5kw
|
YSRO-5T
|
5m3/h
|
DN50
|
DN40
|
DN32
|
2500×1350×2150
|
7.0kw
|
YSRO-8T
|
8m3/h
|
DN50
|
DN50
|
DN40
|
3500×1500×2150
|
11kw
|
YSRO-10T
|
10m3/h
|
DN50
|
DN50
|
DN40
|
3500×1600×2300
|
15kw
|
Key Advantages:
Continuous operation, the product water quality is stable, saving the backwash and cleaning water to produce ultra-pure water with a high yield (the yield can be as high as 95%) No recycled sewage, no sewage treatment facilities no acid and alkali reserve and acid and alkali dilution transport facilities reduce the workshop building area safe and reliable to avoid workers contact with acid and alkali to reduce operation and maintenance costs.
Maintance:
1. The water yield of the machine is more than 1000L/H when the water temperature is 25℃, the water yield will increase or decrease by about 3% when the water temperature rises or falls by 1℃, which is determined by the characteristics of the RO film. 2. The water entering the RO film should strictly control the residual chlorine content below 0.1ppm, the method is: the sampling port of the adsorption filter is connected with water, detected with residual chlorine determination agent, if exceeded, the activated carbon filter material should be replaced. 3. If the water intake is insufficient or the pressure is too low, the water shortage and underpressure system of the machine will automatically stop the equipment.
Contact Us at Any Time