Place of Origin | Zhengzhou ,China |
Brand Name | HYJB |
Model Number | 0.5 tons double-stage |
0.5 tons two-stage reverse osmosis plant for Purifying Mineral Water
Product Description
Reverse osmosis device is to use enough pressure to make the solvent (generally water) in the solution through the reverse osmosis membrane (or semi-permeable membrane) and separated, because this process and natural osmosis in the opposite direction, so it is called reverse osmosis. Reverse osmosis method can be adapted to all kinds of salt content of the raw water, especially in the high salt content of the water treatment works, can obtain very good technical and economic benefits. The desalination rate of the reverse osmosis method is improved, the recovery rate is high, the operation is stable, the floor space is small, the operation is simple, the reverse osmosis equipment removes most of the bacteria, colloid and large molecular weight organic matter while removing the salt.
Parameter Table
Model
|
Water Making Ability
|
Inlet Caliber
|
Effluent Caliber
|
Blowdown alCer
|
Size(mm)
|
Power
|
YSRO-0.5T
|
0.5m3/h
|
DN20
|
DN20
|
DN15
|
1500×600×1500
|
1.3kw
|
YSRO-1T
|
1m3/h
|
DN25
|
DN25
|
DN20
|
1700×600×1500
|
2.1kw
|
YSRO-2T
|
2m3/h
|
DN32
|
DN25
|
DN20
|
2500×1000×1950
|
4.4kw
|
YSRO-3T
|
3m3/h
|
DN40
|
DN32
|
DN25
|
2500×1200×2150
|
4.5kw
|
YSRO-5T
|
5m3/h
|
DN50
|
DN40
|
DN32
|
2500×1350×2150
|
7.0kw
|
YSRO-8T
|
8m3/h
|
DN50
|
DN50
|
DN40
|
3500×1500×2150
|
11kw
|
YSRO-10T
|
10m3/h
|
DN50
|
DN50
|
DN40
|
3500×1600×2300
|
15kw
|
Key Advantage
Reverse osmosis equipment device desalination rate is high, single membrane desalination rate of up to 99%, a reverse osmosis system desalination rate can generally be stabilised at more than 90%, two reverse osmosis system desalination rate can be stabilised at more than 98%. As the reverse osmosis equipment can effectively remove microorganisms, organic matter and iron, silicon and other inorganic substances, the water quality is much better than other methods. Compared with the ion exchange system of pure water, reduce the cost of chemicals consumed due to resin regeneration, labour costs and wastewater treatment due to regeneration and other costs, and reduce environmental pollution.
Maintenance
Due to fluctuations in production, reverse osmosis equipment inevitably has to be shut down frequently, and protective measures must be taken when it is shut down for a short or long period of time. Improper disposal will lead to a decline in membrane performance and is not recoverable.
Short-term preservation applies to the system below 15d out of service, can be used every 1 ~ 3d low pressure flushing method to protect the reverse osmosis equipment. Practice has found that when the water temperature is above 20 ℃, the water in the reverse osmosis equipment will be odorous and deteriorate when stored for 3d, and there is a large number of bacterial reproduction. Therefore, it is recommended that when the water temperature is higher than 20 ℃, every 2d or 1d low-pressure flushing, when the water temperature is lower than 20 ℃, you can every 3d low-pressure flushing, each time after the flushing needs to be closed after the water purification equipment reverse osmosis device on all import and export valves.
Long-term out-of-service protection for more than 15d out-of-service system, which must be used to protect the liquid (biocide) filled with water purification equipment reverse osmosis device for protection. Commonly used biocide formula (composite membrane) for formaldehyde 10 (mass fraction), isothiazolinone 20mg / L, sodium bisulfite 1 (mass fraction).