Place of Origin | Zhengzhou ,China |
Brand Name | HYJB |
Model Number | 0.5 tons double-stage |
0.5 tons of unipolar reverse osmosis equipment For Fast And Effective Water Purification
Product Description
Reverse osmosis water purification equipment will improve the formal pure water production process into one, cabinet shelf open design, easy maintenance. And the reverse osmosis program controller control system automatic operation, the operation process, fault using liquid crystal panel display, simple operation, switching system can be completed with only one switch, greatly improving the stability of the system operation. It can be used as the core equipment of water purification house in community, industrial area, oil field, etc. It can also be used as the water treatment equipment in food, beverage, chemical industry, hospital, electronics and other industries.
Parameter Table
Model
|
Water Making Ability
|
Inlet Caliber
|
Effluent Caliber
|
Blowdown alCer
|
Size(mm)
|
Power
|
YSRO-0.5T
|
0.5m3/h
|
DN20
|
DN20
|
DN15
|
1500×600×1500
|
1.3kw
|
YSRO-1T
|
1m3/h
|
DN25
|
DN25
|
DN20
|
1700×600×1500
|
2.1kw
|
YSRO-2T
|
2m3/h
|
DN32
|
DN25
|
DN20
|
2500×1000×1950
|
4.4kw
|
YSRO-3T
|
3m3/h
|
DN40
|
DN32
|
DN25
|
2500×1200×2150
|
4.5kw
|
YSRO-5T
|
5m3/h
|
DN50
|
DN40
|
DN32
|
2500×1350×2150
|
7.0kw
|
YSRO-8T
|
8m3/h
|
DN50
|
DN50
|
DN40
|
3500×1500×2150
|
11kw
|
YSRO-10T
|
10m3/h
|
DN50
|
DN50
|
DN40
|
3500×1600×2300
|
15kw
|
Key Advantage
Low energy consumption compared with the same flow rate of distilled water, its operating costs are lower. No chemical change: no phase change and no heating. Easy to operate: the whole process can be completed at room temperature. Excellent water quality: As reverse osmosis can effectively remove microorganisms such as bacteria, organic matter and inorganic matter such as metal elements, the quality of water is better than other methods. Perfect system design: perfect system design, reasonable membrane row ratio design, with self-service cleaning, can restore the system performance to a greater extent, so thatLong service life, small footprint, easy installation and low maintenance cost.
Maintenance
Prevents the surface of the reverse osmosis membrane from coming into contact with colloidal substances, microorganisms, or other deposits. Protect the reverse osmosis membrane from harmful chemicals such as nonionic or cationic surfactants, organic solvents, and other harmful chemicals. Ensure that the source water does not contain strong oxidizing agents such as ozone, chlorine and potassium permanganate. The temperature of the feed water needs to be controlled below 45°C to prevent the equipment from being overheated and damaged. The source water must not contain colloidal sulfur to maintain water purity.
Product Display
Contact Us at Any Time