![]() |
Place of Origin | Zhengzhou,China |
Brand Name | HYJB |
Model Number | 0.25T single stage |
0.25 Tons Of Two Cans Of Single-Stage PVC Industrial General Water Treatment Equipment
Production Description:
Reverse osmosis, also known as reverse osmosis, is a membrane separation operation that uses the pressure difference as a driving force to separate the solvent from the solution. Because it is opposite to the direction of natural penetration, it is called reverse osmosis. According to the different osmotic pressure of various materials, reverse osmosis pressure greater than osmotic pressure can be used, that is, reverse osmosis method, to achieve the purpose of separation, extraction, purification and concentration.
Parameter Table:
Model
|
Water Making Ability
|
Inlet Caliber
|
Effluent Caliber
|
Blowdown alCer
|
Size(mm)
|
Power
|
YSRO-0.5T
|
0.5m3/h
|
DN20
|
DN20
|
DN15
|
1500×600×1500
|
1.3kw
|
YSRO-1T
|
1m3/h
|
DN25
|
DN25
|
DN20
|
1700×600×1500
|
2.1kw
|
YSRO-2T
|
2m3/h
|
DN32
|
DN25
|
DN20
|
2500×1000×1950
|
4.4kw
|
YSRO-3T
|
3m3/h
|
DN40
|
DN32
|
DN25
|
2500×1200×2150
|
4.5kw
|
YSRO-5T
|
5m3/h
|
DN50
|
DN40
|
DN32
|
2500×1350×2150
|
7.0kw
|
YSRO-8T
|
8m3/h
|
DN50
|
DN50
|
DN40
|
3500×1500×2150
|
11kw
|
YSRO-10T
|
10m3/h
|
DN50
|
DN50
|
DN40
|
3500×1600×2300
|
15kw
|
Key Advantages:
Stable operation - high efficiency, water quality and quantity
Water purification efficiency - to use industry-specific filtration membranes, water purification faster
Reliable quality - key components are made of food grade stainless steel, corrosion resistant, durable
Maintance:
Cleaning the membrane components in the system; Prepare a germicidal solution with reverse osmosis produced water, and rinse the reverse osmosis system with the germicidal solution; After the reverse osmosis system is filled with germicidal liquid, close the relevant valves so that the germicidal liquid is retained in the system, and make sure that the system is fully filled at this time;If the system temperature is below 27 degrees, it should be operated every 30 days with a new bactericidal solution; If the temperature is higher than 27 degrees, the disinfectant should be replaced every 15 days;Before the reverse osmosis system is put back into use, flush the low pressure water supply system for one hour, and then flush the high pressure water supply system for 5-10 minutes; Regardless of low pressure flushing or high pressure flushing, the system's production water discharge valve should be fully opened. Before the system is restored to normal operation, check and confirm that the product water does not contain any fungicide.
Picture:
Contact Us at Any Time