Place of Origin | Zhengzhou ,China |
Brand Name | HYJB |
Model Number | 0.5 tons double-stage |
0.5 tons of Single-stage reverse osmosis water treatment for Pure Water Production Line
Product Description
Single-stage reverse osmosis equipment is also known as a reverse osmosis equipment, that is, our raw water through the pretreatment system, precision filters, and then through a high-pressure pump will be sent to the reverse osmosis device directly to the output of the product water is called single-stage reverse osmosis. The two-stage reverse osmosis equipment is also known as secondary reverse osmosis, the same is also the raw water pressurized to the pretreatment system coarse filtration, and then into the precision filter filtration, and then through a high-pressure pump pressurized to the first level of reverse osmosis system, and then the output of the system of water from the two high-pressure pumps to the second level of pressure to send to the second level of reverse osmosis system, so that the product of the product out of the water known as two-stage reverse osmosis. Today we will focus on single-stage reverse osmosis equipment.
Parameter Table
Model
|
Water Making Ability
|
Inlet Caliber
|
Effluent Caliber
|
Blowdown alCer
|
Size(mm)
|
Power
|
YSRO-0.5T
|
0.5m3/h
|
DN20
|
DN20
|
DN15
|
1500×600×1500
|
1.3kw
|
YSRO-1T
|
1m3/h
|
DN25
|
DN25
|
DN20
|
1700×600×1500
|
2.1kw
|
YSRO-2T
|
2m3/h
|
DN32
|
DN25
|
DN20
|
2500×1000×1950
|
4.4kw
|
YSRO-3T
|
3m3/h
|
DN40
|
DN32
|
DN25
|
2500×1200×2150
|
4.5kw
|
YSRO-5T
|
5m3/h
|
DN50
|
DN40
|
DN32
|
2500×1350×2150
|
7.0kw
|
YSRO-8T
|
8m3/h
|
DN50
|
DN50
|
DN40
|
3500×1500×2150
|
11kw
|
YSRO-10T
|
10m3/h
|
DN50
|
DN50
|
DN40
|
3500×1600×2300
|
15kw
|
Key Advantage
Components are imported or domestic high-quality products, advanced technology; high degree of integration, reliable quality; high degree of automation, stop immediately in case of failure, with automatic protection; high rate of desalination, up to 99% or more; the use of high-efficiency, low-noise imports of good pressure pumps, to reduce the operating noise; to reduce energy consumption, thereby reducing the operating costs;
Maintenance
Before the raw water enters the reverse osmosis equipment, its SDI15 value should always be kept below 5, and the maximum turbidity of the feed water shall not exceed 1.0, which helps to extend the service life of the membrane. The equipment should be designed to prevent the high pressure pump start and stop when the water hammer generated by the impact of reverse osmosis membrane measures. The pure water produced in the first hour after the start of operation should be discharged to ensure that the water quality meets the standard. Regular and reasonable pretreatment to flush the reverse osmosis membrane is an important step to maintain the performance of the equipment. Avoid adding scale inhibitors during low-pressure flushing, but add them during high-pressure operation flushing, and all wastewater and output water generated during flushing must be discharged in a timely manner.
Product Display
Contact Us at Any Time