Automatic 3 ton of double-stage reverse osmosis equipment for Industrial Applications
Product Description
Reverse osmosis water treatment equipment as a pure water filtration production of special equipment, the use of reverse osmosis membrane selective permeability principle, through the equipment of the high-pressure pump through the reverse osmosis membrane of the raw water to apply a certain pressure, so that the water molecules in the raw water can be dialyzed out through the membrane, while other inorganic salts, microorganisms and organic matter due to the reverse osmosis membrane on the retention of these substances can not pass through the membrane, so that you can obtain pure Non-ionized water.
Reverse osmosis (RO) is an important part of membrane separation technology, under the action of higher than the osmotic pressure of the solution, based on other substances can not pass through the semi-permeable membrane and these substances and water to leave.
Parameter Table
Model
|
Water Making Ability
|
Inlet Caliber
|
Effluent Caliber
|
Blowdown alCer
|
Size(mm)
|
Power
|
YSRO-0.5T
|
0.5m3/h
|
DN20
|
DN20
|
DN15
|
1500×600×1500
|
1.3kw
|
YSRO-1T
|
1m3/h
|
DN25
|
DN25
|
DN20
|
1700×600×1500
|
2.1kw
|
YSRO-2T
|
2m3/h
|
DN32
|
DN25
|
DN20
|
2500×1000×1950
|
4.4kw
|
YSRO-3T
|
3m3/h
|
DN40
|
DN32
|
DN25
|
2500×1200×2150
|
4.5kw
|
YSRO-5T
|
5m3/h
|
DN50
|
DN40
|
DN32
|
2500×1350×2150
|
7.0kw
|
YSRO-8T
|
8m3/h
|
DN50
|
DN50
|
DN40
|
3500×1500×2150
|
11kw
|
YSRO-10T
|
10m3/h
|
DN50
|
DN50
|
DN40
|
3500×1600×2300
|
15kw
|
Key Advantage
1. The reverse osmosis membrane is imported rolled composite membrane. Membrane material: aromatic polyacryl.
2. High water permeability and high desalination rate. Under normal circumstances ≥ 98%
3. High retention and removal of organic matter, colloids, particles, bacteria, viruses, heat sources and so on.
4. Small energy consumption, high water utilization rate, lower operating costs than other desalination equipment.
5. There is no phase change in the separation process, and it has reliable stability.
6. Small size of equipment, simple operation, easy maintenance, strong adaptability, long service life.
Maintenance
After a period of normal operation, membrane elements can become contaminated with suspended or insoluble material that may be present in the feed water. Cleaning should be carried out in a timely manner when the performance of the system decreases by 10% under standard conditions, or when scaling or fouling and plugging apparently occurs. Periodic water flushing and chemical dosing for cleaning can restore the performance of the membrane elements and extend their service life.
System in the short-term stop operation period, should be every 5 days flushing system, flushing after closing the valve to prevent scaling and clogging.
System out of operation for a long period of time (more than 30 days), add 1% sodium bisulfite solution to prevent bacterial propagation.
Product Display