logo
Jingte 'er Environmental Protection Engineering Co.,Ltd
Email henry@henanfoodmachinery.com TEL: +86-0371-65161688
Home > products > Pure Water Equipment >
0.5T Unipolar Reverse Osmosis Water Treatment System For Industrial
  • 0.5T Unipolar Reverse Osmosis Water Treatment System For Industrial
  • 0.5T Unipolar Reverse Osmosis Water Treatment System For Industrial

0.5T Unipolar Reverse Osmosis Water Treatment System For Industrial

Place of Origin Zhengzhou ,China
Brand Name HYJB
Model Number 0.5 tons single-stage
Product Details
Material:
PVC
Productivity:
500L/Hour
Water Temp:
5-40℃
Core Components:
Pump, Engine
Qualtity Of Tank:
Three
Marketing Type:
Ordinary Product
Highlight: 

0.5T Industrial Reverse Osmosis System

,

Unipolar Reverse Osmosis System

,

0.5T Reverse Osmosis System

Payment & Shipping Terms
Minimum Order Quantity
1 set
Price
negotiable
Packaging Details
wooden case
Delivery Time
7 days
Payment Terms
L/C,D/A,D/P,T/T,T/T,Western Union,MoneyGram
Supply Ability
200 sets /month
Product Description

0.5T Unipolar Reverse Osmosis Water Treatment System For Industrial Use


Product Description


This product is a 0.5 ton single pole reverse osmosis water treatment equipment, using advanced reverse osmosis technology, designed specifically for small and medium-sized water treatment needs. This equipment can effectively remove impurities such as dissolved salts, organic matter, microorganisms, bacteria, etc. from water, providing high-purity and high-quality water.


Parameter Table


Model
Water Making Ability
Inlet Caliber
Effluent Caliber
Blowdown alCer
Size(mm)
Power
YSRO-0.5T
0.5m3/h
DN20
DN20
DN15
1500×600×1500
1.3kw
YSRO-1T
1m3/h
DN25
DN25
DN20
1700×600×1500
2.1kw
YSRO-2T
2m3/h
DN32
DN25
DN20
2500×1000×1950
4.4kw
YSRO-3T
3m3/h
DN40
DN32
DN25
2500×1200×2150
4.5kw
YSRO-5T
5m3/h
DN50
DN40
DN32
2500×1350×2150
7.0kw
YSRO-8T
8m3/h
DN50
DN50
DN40
3500×1500×2150
11kw
YSRO-10T
10m3/h
DN50
DN50
DN40
3500×1600×2300
15kw



Key Advantage


1. High processing efficiency
Single stage reverse osmosis design, fully utilizing water pressure potential energy to improve water treatment efficiency. The equipment produces a large amount of water per unit time, meeting the demand for rapid water use.
2. High effluent quality
By using high-precision reverse osmosis membrane filtration, soluble salts, organic matter, heavy metal ions, etc. in water are effectively removed, ensuring that the effluent quality meets high standard requirements.
3. Low operating costs
The equipment adopts energy-saving design to reduce energy consumption and operating costs. At the same time, the reverse osmosis membrane has a long lifespan, a long replacement cycle, and reduces maintenance costs.


Maintenance


1. Cleaning: Regularly perform chemical cleaning on the reverse osmosis membrane based on the inlet water quality and operating conditions. Generally, it should be cleaned every 3-6 months. If the incoming water quality is poor or the membrane components are severely contaminated, the cleaning cycle should be shortened. Choose appropriate cleaning agents, such as acidic cleaning agents for removing carbonate scale, metal oxides, etc., and alkaline cleaning agents for removing organic matter, microorganisms, and other pollutants. The cleaning process is strictly carried out in accordance with the operating procedures to avoid damaging the membrane components due to improper operation.
2. Storage: When the equipment is shut down for a long time (more than 7 days), the reverse osmosis membrane needs to be protected. Fill the membrane element with chemical agents to prevent microbial growth and dehydration of the membrane element. The commonly used protective solution is a 1% sodium bisulfite solution. During storage, regularly check the concentration and pH value of the protective solution to ensure its effectiveness. Before restarting the device, rinse the protective solution thoroughly with clean water.
3. Replacement: Reverse osmosis membranes have a certain service life, usually 3-5 years. When the desalination rate of the membrane element drops to 85% -90% of the initial value, or the water production rate drops to 70% -80% of the initial value, and cannot be restored through chemical cleaning, the membrane element needs to be replaced in a timely manner to ensure the quality of the water production and the normal operation of the equipment.
 

Product Display


0.5T Unipolar Reverse Osmosis Water Treatment System For Industrial 00.5T Unipolar Reverse Osmosis Water Treatment System For Industrial 10.5T Unipolar Reverse Osmosis Water Treatment System For Industrial 20.5T Unipolar Reverse Osmosis Water Treatment System For Industrial 30.5T Unipolar Reverse Osmosis Water Treatment System For Industrial 40.5T Unipolar Reverse Osmosis Water Treatment System For Industrial 5




Contact Us at Any Time

+86-0371-65161688
Building 30, Zhengzhou Equipment Manufacturing Industrial Park, No.1 Science and Technology Road 2, Xingyang, Zhengzhou, Henan, China
Send your inquiry directly to us